Our Technology
Home/Products/Immunofluorescence-Platform/Instruments/Finecare™ FIA Meter III Plus
Finecare™ FIA Meter III Plus
Finecare™ FIA Meter III Plus is a fluorescence immunochromatographic semi-automatic analysing system with internal temperature control. It can test 20 items at the same time and help diagnose conditions such as infection, diabetes, cardiovascular diseases, renal injury and hormone, etc. Finecare™ FIA Meter III Plus fluorescent analyzer is a closed system.
Test Menu
  • COVID-19
    Items Sample Types Sample Size Reaction Time Measuring Range Clinical Reference
    2019-nCoV Antibody Whole Blood
    Serum
    Plasma
    10μL 10 mins Qualitative  Negative
    2019-nCoV IgM Qualitative  Negative
    2019-nCoV IgM/IgG Qualitative  Negative
    2019-nCoV Antigen NP/OP / 15 mins Qualitative Negative
    2019-nCoV RBD Antibody Fingerstick or Venous
    WB/S/P
    20μL 15 mins Qualitative Negative

  • Vitamin
    Items Sample Types Sample Size Reaction Time Measuring Range Clinical Reference
    Vitamin D Serum
    Plasma
    75μL 15min 5-100 ng/mL 30-100 ng/mL

  • Diabetes & Renal Injury
    Items Sample Types Sample Size Reaction Time Measuring Range Clinical Reference
    HbA1c Whole Blood
    (Fingerstick/Venous)
    10μL 5 mins 4.0-14.5% 4-6.5%
    MAU Urine  75μL 3 mins 5-300 mg/L 0-20 mg/L
    CysC Whole Blood
    Serum
    Plasma
    10μL 5 mins 0.2-10 mg/L 0.5-1.1mg/L
    β2-MG Whole Blood
    Serum
    Plasma
    10μL 10 mins 0.3-20 mg/L 1.0-2.7 mg/L
    NGAL Urine  75μL 15 mins 10-1500 ng/mL ≤131.7ng/mL

  • Thyroid Function
    Items Sample Types Sample Size Reaction Time Measuring Range Clinical Reference
    T3 Whole Blood
    Serum
    Plasma
    75μL 15 mins 0.61-9.22nmol/L 1.23-3.07nmol/L
    T4 12.87-300nmol/L 66-181 nom/L
    TSH 0.1-100 mlU/L 0.3-4.2mlU/L
    fT3 0.40-50.00pmol/L (0.26-32.55pg/mL) 2.8-7.1pmol/L
    (1.82-4.61 pg/ml)
    fT4 1.00-100 pmol/L (0.078-7.77ng/dl) 12-22 pmol/L
    (0.94-1.72 ng/dL)

  • Fertility
    Items Sample Types Sample Size Reaction Time Measuring Range Clinical Reference
    β-HCG Whole Blood
    Serum
    Plasma
    20μL 15 mins 2-200,000mlU/mL 5 mlU/mL
    LH Whole Blood
    Serum
    Plasma
    75μL 15 mins 1-100mlU/mL Male:
    1.70-8.60 mIU/mL;
    Female:
    Follicular phase: 2.95-13.65 mIU/mL
    Ovulation phase:13.65-95.75 mIU/mL
    Luteal phase:1.25-11.00 mIU/mL
    Menopause phase:8.24-55.23 mIU/mL
    FSH Whole Blood
    Serum
    Plasma
    75μL 15 mins 1-100mlU/mL Male:
    1.50-12.40 mIU/mL
    Female:
    Follicular phase:4.46-12.43 mIU/mL
    Ovulation phase:4.88-20.96 mIU/mL
    Luteal phase:1.96-7.70 mIU/mL
    Menopause phase: 22.70-130.00 mIU/mL
    Prog Whole Blood
    Serum
    Plasma
    75μL 15 mins 1.5-60ng/mL Male:
    0.2-1.5 ng/mL
    Female:
    Follicular phase: 0.2-2.0 ng/mL
    Ovulation phase: 0.7-3.5 ng/mL
    Luteal phase: 3.0-30 ng/mL
    Menopause phase: 0.1-0.9 ng/mL
    7 weeks of pregnancy: 24.5±7.6 ng/mL
    9-12 weeks of pregnancy: 38.0±13.0 ng/mL
    PRL Whole Blood
    Serum
    Plasma
    75μL 15 mins 1-200ng/mL Female(non-pregnant):
    4.60-25.07 ng/mL
    Male:
    3.45-17.42 ng/mL
    E2 Whole Blood
    Serum
    Plasma
    75μL 15 mins 9-3000pg/mL Male: <85 pg/mL
    Female:
    Follicular Phase: 12-262 pg/mL
    Ovulation: 40-396 pg/mL
    Luteal Phase: 21-381 pg/mL
    Menopause: <190 pg/mL
    Pregnancy: >145 pg/mL
    Testosterone Whole Blood
    Serum
    Plasma
    75μL 15 mins 0.2-15ng/mL Male:
    20-49 years old, 1.61-8.41 ng/mL
    ≥50 years old, <0.61 ng/mL
    Female:
    20-49 years old, ≤0.80 ng/mL
    ≥50 years old, <0.71 ng/mL
    AMH Whole Blood
    Serum
    Plasma
    75μL 15 mins 0.1-16ng/mL Male:
    20-60 years old, 0.92-13.89 ng/mL
    Female:
    20-29 years old, 0.88-10.35 ng/mL
    30-39 years old, 0.31-7.86 ng/mL
    40-50 years old, ≤5.07 ng/mL

  • Cardiac Markers
    Items Sample Types Sample Size Reaction Time Measuring Range Clinical Reference
    NT-proBNP Whole Blood
    Serum
    Plasma
    75μL 15 mins 18-35000pg/mL <75 years old
    0-300 pg/mL
    ≥ 75 years old
    0-450 pg/mL
    CTnI 0.1-50ng/mL 0-0.3 ng/mL
    Myo 2.0-400ng/mL 0-58 ng/mL
    CK-MB 0.3-100ng/mL 0-5 ng/mL
    3 in 1
    (cTnl/MYO/CK-MB)
    Same with the single item Same with the single item
    BNP Whole Blood
    Plasma
    5-5000pg/mL 0-100 pg/mL
    H-FABP Whole Blood
    Serum
    Plasma
    1-120ng/mL 0-7ng/mL
    2 in 1
    (cTnl/NT-proBNP)
    Same with the single item Same with the single item
    hsCRP 10μL 3 mins 0.1-10 mg/L ≤1.0 mg/L
    cTnT 100μL for whole blood;
    75μL for plasma/serum
    15 mins 0.003-10 ng/mL 0-0.1 ng/mL
    Lp-PLA2 75μL 10-1000 ng/mL <225 ng/mL

  • Coagulation
    Items Sample Types Sample Size Reaction Time Measuring Range Clinical Reference
    D-Dimer Whole Blood
    Plasma
    15μL for whole blood
    10μL for plasma
    5 mins 0.1-10 mg/L 0-0.5 mg/L
    D-Dimer
    one-step
    100μL for whole blood
    75μL for plasma
    15 mins 0.1-10 mg/L 0-0.5 mg/L

  • Inflammation Markers
    Items Sample Types Sample Size Reaction Time Measuring Range Clinical Reference
    PCT Whole Blood
    Serum
    Plasma
    75μL for whole blood
    50 μL for serum/plasma
    15 mins 0.1-100ng/mL 0-0.5 ng/L
    CRP (hsCRP+CRP) 8.5μL for whole blood
    5 μL for serum/plasma
    3 mins 0.5-200mg/L CRP: 0-10 mg/L
    HsCRP: 0-1 mg/L
    SAA 10μL 15 mins 1.0-300mg/L 0-10 mg/L
    2 in 1 (CRP+PCT) 75μL CPR: 0.5-150mg/L
    PCT: 0.1-100mg/L 
    CPR: <10mg/L
    PCT: <0.5mg/L
    IL-6 75μL 3-4000 pg/Ml ≤10 pg/mL

  • Tumor Markers
    Items Sample Types Sample Size Reaction Time Measuring Range Clinical Reference
    AFP Whole Blood
    Serum
    Plasma
    75μL 15 mins 5-400 ng/mL 0-20 ng/mL
    PSA 2-100 ng/mL 0-4 ng/mL
    CEA 1-500 ng/mL 0-5 ng/mL
    fPSA 0.2-30 ng/mL <1 ng/mL

  • Others
    Items Sample Types Sample Size Reaction Time Measuring Range Clinical Reference
    Cortisol Whole Blood
    Serum
    Plasma
    75μL 15 mins 50~1000 nmol/L 7:00~10:00a.m.:
    134~522nmol/L
    4:00~8:00p.m.
    77~317nmol/L
    S100β 15 mins 0.05~10 ng/mL < 0.2 ng/mL
    Ferritin 10 mins 5 ~ 1000 ng/mL Male 30-400 ng/mL
    Female 13-150 ng/mL
    Vitamin D Serum/Plasma 15 mins 5-100 ng/mL 30-100 ng/mL

Benefits
  • Rapid Test
    Rapid Test
    Fast Detection, running 200 tests per hour.
  • Multi-Channel for Higher Throughput
    Multi-Channel for Higher Throughput
    20 channels, test more items at one time.
  • Accurate & Reliable
    Accurate & Reliable
    Good Correlation with CLIA method.
  • Temperature Control
    Temperature Control
    Provide Better Reaction Condition.
Specification
Description
Technologies Built-in thermal printer
10'' LED touch screen
LIS/HIS connection
ID chip 
Sample size 75μL
Standards CE, NGSP, IFCC
Dimension (H×W×D) 480.5x396x374mm
Weight 19.5kg
Application Laboratory, ER, ICU, Clinics, GP office

Download Brochure of Finecare™ FIA Meter III Plus
Get Free Quote Now
If you’re interested in our products or service, please leave your information here, and we will be in touch with you shortly.
*
*
*
*
*
*
Submit
Download Brochure of Finecare™ FIA Meter III Plus
HOW CAN WE HELP?
Wondfo is committed to quality customer service. If you have any question, please feel free to contact us.
Request
This website uses cookies. By continuing to browse or by clicking “Accept”, you agree to our use of cookies to enhance your experience.
Accept

Choose your location

It looks like you are located in: Spain
You are trying to view a page from a different country or region. *Not all products and services may be available in your country or region.